Operating mode Flow rate (Q) B* C*
Normal
Flow
Rate
Idling mode 0 < Q < 0.1 x Qnom X
Optimal mode 0.1 x Qnom < Q < 1.5 x Qnom X
Overload mode 1.5 x Qnom < Q < 2 x Qnom X
Tampering
Rate
Tampering mode 2 x Qnom < Q < 10 x Qnom X X
Air blowing submode Q > 10 x Qnom X X

Qnom = nominal fuel flow (see product page for the right value for your instrument)