MV-302 Mass flow regulator
                            
                    Mass Flow Regulator for gases with integrated display
- Direct thermal mass flow measurement
 - High accuracy
 - 10 pre-installed gases
 - Bright, graphical OLED display
 - Digital or analog output; alarm and counter functions
 - High precision needle valve
 
Multi gases
        Valve
        Pre-installed ranges
| Ranges | Flow range (relative Air) | 
|---|---|
| Range 1 | 20 mln/min .. 2000 mln/min (sccm) | 
| Range 2 | 20 mln/min .. 1000 mln/min (sccm) | 
| Range 3 | 20 mln/min .. 500 mln/min (sccm) | 
| Range 4 | 20 mln/min .. 200 mln/min (sccm) | 
Pre-installed gases
| Gases | min. range .. max. range | 
|---|---|
| Air, N2, O2, CO2, CO and N2O  | 20 .. 2000 mln/min (sccm) | 
| Ar | 40 .. 4000 mln/min (sccm) | 
| CH4, C3H8 and C4H10 | 10 .. 1000 mln/min (sccm) | 
Features of MV-302 Mass flow regulator
- Clear indication in:
- actual flow rate (bar graph and value)
- desired flow units
- type of gas
- totalised flow - Bright, wide-angle OLED display
 - Free of parallax error
 - Virtually independent of temperature and
pressure variations - Low pressure drop
 - Wide flow ranges
 - Fast response
 - High accuracy
 - Electronic output:
- Analog (0 .. 5 Vdc)
- RS-232 interface (with Bronkhorst FlowSuite 2)
- Modbus-RTU/ASCII interface - Configurable password protection
 - Alarm and counter functions
 - Relays
 - Multi Gas / Multi Range
 - 10 Pre-installed gases
 - High resolution needle valve
 - Digitally calibrated
 - Free software tools
 
Scope of delivery
- MASS-VIEW flow meter
 - packing box
 - 9.17.054 Short form manual
 - (optional) fittings
 - (optional) power supply
 
Please note:
Our mass flow meters are sold without fittings and without power supply, please use the 'Accessories' tab to order additional accessories. 
For your convenience, we also have our flow ranges in other flow units.
Technical specifications
Measurement / control system
Flow range 
                
                    
                    
                    
                    
                    20 .. 2000 mln/min (sccm)
Mass flow units ln/min and SLM refer to normal operating conditions, i.e. 0°C (32°F) and 1013 mbar (14.7 psi)
            Mass flow units ln/min and SLM refer to normal operating conditions, i.e. 0°C (32°F) and 1013 mbar (14.7 psi)
Accuracy
                
                    
                    
                    
                    
                    ± 2% RD for flow > 50% of max. capacity
± (1% RD + 0.5% FS) on lower flows
Technical specifications are based on Air at maximum FS
            ± (1% RD + 0.5% FS) on lower flows
Technical specifications are based on Air at maximum FS
Repeatability
                
                    
                    
                    
                    
                    < 0.2% FS typical
                
            Turndown ratio
                
                    
                    
                    
                    
                    up to 1:100
                
            Operating pressure
                
                    
                    
                    
                    
                    0 … 10 bar(g) / 0 … 150 psi(g)
                
            Pressure coefficient
                
                    
                    
                    
                    
                    0.2% / bar typical at Air
                
            Pre-installed gases
                
                    
                    
                    
                    
                    Air, N2, O2, CO2, CO, N2O, Ar, CH4, C3H8 and C4H10
                
            Standard calibration gas
                
                    
                    
                    
                    
                    Air, other gases are converted using our Fluidat® conversion model which will introduce extra inaccuracy
                
            Response time (sensor)
                
                    
                    
                    
                    
                    (t63%) 	2 seconds
                
            Operating temperature
                
                    
                    
                    
                    
                    0 … 50 °C (32 … 122°F)
                
            Temperature coefficient
                
                    
                    
                    
                    
                    Zero: <0.1%FS/°C, Span: <0.2%RD/°C
                
            Leak integrity, outboard
                
                    
                    
                    
                    
                    tested < 2 x 10-9 mbar l/s He
                
            Attitude sensitivity
                
                    
                    
                    
                    
                    < 0,1 % FS
                
            Mechanical parts
Material (wetted parts)
                
                    
                    
                    
                    
                    Meter: aluminium, Viton® (FPM)
Needle Valve: Fluorisint, Brass, Buna N
            Needle Valve: Fluorisint, Brass, Buna N
Process connections
                
                    
                    
                    
                    
                    G 1/4" BSPP female
(compression fittings optional)
            (compression fittings optional)
Sealing material
                
                    
                    
                    
                    
                    Viton®, PTFE
                
            Weight
                
                    
                    0.7
                    
                    kg
                    
                
            Ingress protection
                
                    
                    
                    
                    
                    IP40
                
            Electrical properties
Power supply
                
                    
                    
                    
                    
                    +15 … 24 Vdc (+/- 10%)
                
            Max. power consumption
                
                    
                    
                    
                    
                    approx. 135 mA
                
            Output
                
                    
                    
                    
                    
                    0 .. 5 Vdc
                
            EMC
                
                    
                    
                    
                    
                    EU declaration
                
            Digital Communication
                
                    
                    
                    
                    
                    RS232 / RS485 (Modbus-RTU/ASCII)
                
            Min. And max. Relay contacts
                
                    
                    
                    
                    
                    switching current 0.5 A, 24 Vdc
one side grounded (0 Vdc power)
            one side grounded (0 Vdc power)
Electrical connection
                
                    
                    
                    
                    
                    8-pin RJ-45 modular jack
                
            Downloads
Brochure & Certificate
Dimensional drawing
Pressure drop
Stepfile
Applications
The fields of application for MASS-VIEW® mass flow meters are diverse:
- Burner Control (furnace construction)
 - Welding (welding gas monitoring)
 - Leak measurements (quality, environment)
 - Coating (equipment construction)
 - Regulation of gaseous atmospheres (biotechnology)
 - Measurements of gas consumption (hospitals)
 - Test equipment (production maintenance)
 - Local preparation of a gas mixture
 - Flow rate monitoring (laboratories)
 - Cutting (steel sheets)
 - Cost centre billing
 - Analytical equipment
 - Aeration / sparging (food products, ice cream / edible oils
 - Blanketing (food)
 - Fermentation (food, biotechnology, pharma)
 
Frequently Asked Questions
- Calibration Interval
 - Calibration Interval
 - How to connect MASS-VIEW® using RS-232 to a computer?
 - How to connect several MASS-VIEWs (5, 6, 7) to a RS-485 bus system?
 - What do ln/min, Is/min, slm and sccm stand for?
 - Which counter units are available to select?
 - Which maximum capacity does a MASS-VIEW® flow meter have?
 - What is the sensor principle of MASS-VIEW?
 
More questions on our FAQ page
                                                
                                                