                            Magnetic Flow Meter [12.5 .. 250 lpm, 4 .. 20 mA]
The MAG-VIEW™ series operate on the magnetic inductive principle. The complete absence of moving parts, its interference free operation and the insensitivity with contaminated liquids, makes this magnetic flow meter the perfect solution even in compact machines with cramped confines.
                    The MAG-VIEW™ series operate on the magnetic inductive principle. The complete absence of moving parts, its interference free operation and the insensitivity with contaminated liquids, makes this magnetic flow meter the perfect solution even in compact machines with cramped confines.
Water like liquids
        Frequency and Analog 4..20mA
        Flow ranges
This magnetic flow meter is suitable to measure flows of water and other conductive liquids within a flow range of 12.5 .. 250 lpm.
| Model | Min | Max | output signal starts | 
|---|---|---|---|
| MVM-250-QA | 12.5 l/min | 250 l/min | ~ 5 l/min | 
Scope of delivery
- Magnetic Flow Meter
 - Calibration certificate
 - Packing box
 - MAG-VIEW Manual
 - (optional) instrument cable
 
Features of MVM-250-QA Magnetic Flow Meter
- Makes liquid flows visible by
- Frequency output
 - Analog output (4..20 mA)
 - Blinking LED (green)
 
 - No mechanical wear
 - No moving parts
 - Ease of mounting and operation
 - Mounting in any position
 - Free pipe cross section
 - No additional pressure drop
 - Fast response (<100 ms)
 - Insensitive with contaminated liquids
 - Ideal solution for interference free operation combined with a long-life cycle
 - Can be used in areas where flow sensors with moving parts cannot be applied
 - Wide independence to the inlet and outlet pipe creates the advantage to be able to install in compact machines with cramped confines
 
Technical specifications
Measurement / control system
Flow range 
                
                    
                    
                    
                    
                    12.5 … 250 l/min
                
            Accuracy
                
                    
                    
                    
                    
                    ±0.7 % of reading ±0.3 % of range
(incl. factory calibration certificate; test conditions: water 23°C)
            (incl. factory calibration certificate; test conditions: water 23°C)
Repeatability
                
                    
                    1
                    
                    %
                    FS
                
            Max. flow rate
                
                    
                    
                    300
                    l/min
                    
                
            Temperature rating
                
                    
                    
                    
                    
                    Ambient temperature: -15..60°C
Storage temperature: -15..60°C
            Storage temperature: -15..60°C
Operating pressure
                
                    
                    
                    
                    
                    10 bar(a) (20 °C), 8 bar(a) (40 °C), 6 bar(a) (60 °C), 5 bar(a) (80 °C)
                
            Nominal diameter
                
                    
                    
                    
                    
                    DN 25
                
            Flow / alarm indication
                
                    
                    
                    
                    
                    Green LED: flow proportional flashing
                
            Signal output starting from
                
                    ~
                    5
                    
                    l/min
                    
                
            Medium
                
                    
                    
                    
                    
                    Water and other conductive liquids
(minimum conductivity of 20 μS/cm)
            (minimum conductivity of 20 μS/cm)
Medium Temperature
                
                    
                    
                    
                    
                    ± -15.. 80 °C (not freezing)
                
            Rangeability
                
                    
                    
                    
                    
                    1:20
                
            Response time (sensor)
                
                    <
                    
                    
                    
                    100 ms
                
            Mechanical parts
Material (wetted parts)
                
                    
                    
                    
                    
                    Housing: ABS
In contact with fluid:
Electrodes and ground rings: Stainless Steel 1.4404
Process connections: PVDF
Measuring pipe: PVDF
O-Rings: EPDM
            In contact with fluid:
Electrodes and ground rings: Stainless Steel 1.4404
Process connections: PVDF
Measuring pipe: PVDF
O-Rings: EPDM
Process connections
                
                    
                    
                    
                    
                    G1¼'' BSP male thread
                
            Sealing material
                
                    
                    
                    
                    
                    EPDM
                
            Weight
                
                    
                    1
                    
                    kg
                    
                
            Ingress protection
                
                    
                    
                    
                    
                    IP65 
                
            Electrical properties
Power supply
                
                    
                    12 ..
                    24
                    Vdc
                    ±10%
                
            Max. power consumption
                
                    
                    
                    
                    
                    Typical 1.1 W, max. 3.6 W
                
            Electrical protection measures
                
                    
                    
                    
                    
                    short-circuit proof,
protected against polarity reversal
            protected against polarity reversal
Analog output
                
                    
                    
                    
                    
                    4 … 20 mA
                
            Frequency output
                
                    
                    
                    
                    
                    Pulse rate / K-factor : 80 pulses/l
Resolution : 12,5 ml/pulse
Signal shape : Push-Pull
            Resolution : 12,5 ml/pulse
Signal shape : Push-Pull
Signal shape
                
                    
                    
                    
                    
                    Square wave signal, duty cycle 50:50 (Push-Pull)
                
            Signal current
                
                    
                    
                    
                    
                    Max. 100 mA
                
            Pin assignment
                
                    
                    
                    
                    
                    PIN 1: +12…24 VDC+10%
PIN 2: Analog output 4..20mA
PIN 3: -GND
PIN 4: Frequency output(Push-pull)
            PIN 2: Analog output 4..20mA
PIN 3: -GND
PIN 4: Frequency output(Push-pull)
Electrical connection
                
                    
                    
                    
                    
                    4-pin-plug M12x1
                
            Downloads
Manuals
Declaration of Conformity
Stepfile
Applications
The fields of application for this magnetic flow meter are diverse:
- Can be used in areas where flow sensors with moving parts (paddle wheel, turbine sensors) cannot be applied due to contaminated media
 - Sensor is intended for continuously measuring of flow rates or for dosing / batching of electrically conductive liquids with a minimum of 20µS/cm
 - Water distribution
 - Chemical feed
 - Measuring of cooling water, measuring of waste water 
 - Cleaning Industry: Dosing of detergents and other additives
 - Agriculture: dosing of water, fertilizer, fungicides and pesticides, measuring of water and liquid feed supplements
 - Exhaust Gas Cleaning: Dosing of AdBlue
 
Frequently Asked Questions
- Can the MAG-VIEW QA-series be used with low viscosity mineral slurries?
 - Is the MAG-VIEW sensitive to air bubbles?
 - MAG-VIEW export codes (TARIC, HS, ECCN and Country of origin)
 - The fluid conductivity changes during the measurements, is that a problem?
 - Can the MAG-VIEW be used with demineralized – deionized water?
 
More questions on our FAQ page
                                                