Technical Specifications
Performance
|
Specifications
|
Accuracy |
±1.5% RD, ±0.3% FS |
Reproducibility |
1% |
Rangeability |
1:60
|
Signal output starting from
|
~ 0.9 l/min
|
Medium |
Water and other conductive liquids with a minimum conductivity of 50 μS/cm (lower conductivity affects the accuracy) |
Operating temperature
|
-20...90 °C |
Nominal pressure
|
PN 16 |
Nominal diameter
|
DN 10
|
Process connection
|
½'' BSP male thread |
Flow indication
|
LED green, flow proportional flashing
|
Response time
|
< 500 ms |
Mechanical
|
Specifications
|
Materials (wetted parts) |
Housing: Aluminium pressure diecasted Electrodes: Stainless Steel 1.4571 Process connections: Stainless Steel 1.4571 Measuring pipe: PEEK-GF30 Gasket: EPDM
|
Protection |
IP65 and IP67 with MFO.CB.25
|
Electrical
|
Specifications
|
Frequency output
|
|
Pulse rate
|
500 pulses/l |
Resolution
|
2 ml/pulse |
Signal shape
|
Square wave signal, duty cycle 50:50 Push-Pull • NPN open collector [o.c.] • PNP o.c. |
Signal current
|
max. 100 mA, current limited |
Electrical connection
|
5-pin-plug M12x1
|
Power supply
|
24 VDC±10% |
Power consumption
|
max. 150 mA
|
Pin assignment
|
 |
PIN 1: +U PIN 2: PIN 3: GND PIN 4: frequency output NPN PIN 5: do not connect |
|
Pressure Drop

Connection to a PLC
Most digital PLC inputs are designed for connection to PNP signals. The MAG-VIEW™ has an NPN frequency signal with an integrated 2kΩ pull-up resistor. Its signal current of ~12 mA is recognised as a signal by the current PLC. Thus, operating a MAG-VIEW™ with a PLC should not present any problems. The frequency output of the MAG-VIEW™ should be attached to a digital input of the PLC.